Tools · Hydrology
River design discharge
Guided step by step: the 50-year flood by RDSO’s RBF-16 for small catchments, the CWC Flood Estimation Report unit hydrograph method for each subzone (25 to 2500 km²), the empirical formulas of Dicken, Ryve and Inglis, the area–velocity method from the HFL at site, then compare them and adopt a design discharge.
Guided · step 1 of 7
Collect the catchment data
From the topo sheet: catchment area A up to the bridge site, length L of the longest stream, and the fall H from the farthest point of the catchment to the bridge bed. From the rainfall atlas of your subzone: the 50-year 24-hour point rainfall R. RBF-16 applies to catchments smaller than 25 km²; larger ones (25 to 2500 km²) use the CWC Flood Estimation Report method for the subzone.
A = 2.54 km², L = 2.5 km, H = 67.25 m, R = 16 cm
Soil: red soil, clayey loam, cultivated plains, tall crops, wooded areas
Catchment
Catchment and stream
RBF-16 tables
| Table 1: F | tc < 30 min | 30 to 60 min | 60 to 100 min |
|---|---|---|---|
| Below 2.5 km² | 0.72 | 0.81 | 0.88 |
| 2.5 to 5.0 km² | 0.71 | 0.8 | 0.87 |
| 5.0 to 13.0 km² | 0.7 | 0.79 | 0.86 |
| 13.0 to 25.0 km² | 0.68 | 0.78 | 0.85 |
| Table 2: soil and cover | X |
|---|---|
| Sandy soil, sandy loam, arid areas | 0.249 |
| Alluvium, silt loam, coastal areas | 0.332 |
| Red soil, clayey loam, cultivated plains, tall crops, wooded areas | 0.415 |
| Black cotton, clayey soil, lightly covered, plain and barren | 0.456 |
| Hilly soils, plateau and barren | 0.498 |
Short-duration rainfall ratio (after Fig. 4)
Approximate curve fitted to RBF-16’s worked examples. Read the exact ratio from Fig. 4 for your subzone and type it in on the left if it differs.
Full solution, all steps at once
- Collect the catchment data
A = 2.54 km², L = 2.5 km, H = 67.25 m, R = 16 cm
Soil: red soil, clayey loam, cultivated plains, tall crops, wooded areas
- Time of concentration tctc = (L³H)0.345
tc = (2.5³67.25)0.345 = (15.62567.25)0.345 = 0.23230.345
tc = 0.604 h = 36.3 min
- Areal reduction factor F (Table 1)
A = 2.54 km² → row “2.5 to 5.0 km²”; tc = 36.3 min → column “30 to 60 min”
F = 0.8
- Runoff coefficient CC = X·(R·F)0.2
X = 0.415 (Table 2)
C = 0.415 × (16 × 0.8)0.2 = 0.415 × 12.80.2 = 0.415 × 1.6651 = 0.691
- Rainfall during tcR₅₀(tc) = R₅₀(24 h) × ratio(tc)
ratio at tc = 0.6 h: 0.282
R₅₀(tc) = 16 × 0.282 = 4.512 cm
- Rainfall intensity I₅₀I₅₀ = R₅₀(tc)tc
I₅₀ = 4.5120.604 = 7.465 cm/h = 74.65 mm/h
- Design discharge Q₅₀Q₅₀ = 0.278·C·I₅₀·A
Q₅₀ = 0.278 × 0.691 × 74.65 × 2.54 = 36.43 m³/s
This is the 50-year flood used for railway bridge waterway, scour depth and HFL.