← All tools

Tools · Hydrology

River design discharge

Guided step by step: the 50-year flood by RDSO’s RBF-16 for small catchments, the CWC Flood Estimation Report unit hydrograph method for each subzone (25 to 2500 km²), the empirical formulas of Dicken, Ryve and Inglis, the area–velocity method from the HFL at site, then compare them and adopt a design discharge.

Guided · step 1 of 7

Collect the catchment data

From the topo sheet: catchment area A up to the bridge site, length L of the longest stream, and the fall H from the farthest point of the catchment to the bridge bed. From the rainfall atlas of your subzone: the 50-year 24-hour point rainfall R. RBF-16 applies to catchments smaller than 25 km²; larger ones (25 to 2500 km²) use the CWC Flood Estimation Report method for the subzone.

A = 2.54 km², L = 2.5 km, H = 67.25 m, R = 16 cm

Soil: red soil, clayey loam, cultivated plains, tall crops, wooded areas

Catchment

Catchment and stream

farthest pointbridge siteL = 2.5 kmA = 2.54 km²H = 67.3 mSketch only: not to scale
Q₅₀
36.43m³/s
tc
0.604h
36.3 min
C
0.691
I₅₀
74.7mm/h

RBF-16 tables

Table 1: Ftc < 30 min30 to 60 min60 to 100 min
Below 2.5 km²0.720.810.88
2.5 to 5.0 km²0.710.80.87
5.0 to 13.0 km²0.70.790.86
13.0 to 25.0 km²0.680.780.85
Table 2: soil and coverX
Sandy soil, sandy loam, arid areas0.249
Alluvium, silt loam, coastal areas0.332
Red soil, clayey loam, cultivated plains, tall crops, wooded areas0.415
Black cotton, clayey soil, lightly covered, plain and barren0.456
Hilly soils, plateau and barren0.498

Short-duration rainfall ratio (after Fig. 4)

0.250.51236122400.20.40.60.81tc = 0.6 h → 0.282Duration (h), log scaleratio

Approximate curve fitted to RBF-16’s worked examples. Read the exact ratio from Fig. 4 for your subzone and type it in on the left if it differs.

Full solution, all steps at once
  1. Collect the catchment data

    A = 2.54 km², L = 2.5 km, H = 67.25 m, R = 16 cm

    Soil: red soil, clayey loam, cultivated plains, tall crops, wooded areas

  2. Time of concentration tctc = (L³H)0.345

    tc = (2.5³67.25)0.345 = (15.62567.25)0.345 = 0.23230.345

    tc = 0.604 h = 36.3 min

  3. Areal reduction factor F (Table 1)

    A = 2.54 km² → row “2.5 to 5.0 km²”; tc = 36.3 min → column “30 to 60 min”

    F = 0.8

  4. Runoff coefficient CC = X·(R·F)0.2

    X = 0.415 (Table 2)

    C = 0.415 × (16 × 0.8)0.2 = 0.415 × 12.80.2 = 0.415 × 1.6651 = 0.691

  5. Rainfall during tcR₅₀(tc) = R₅₀(24 h) × ratio(tc)

    ratio at tc = 0.6 h: 0.282

    R₅₀(tc) = 16 × 0.282 = 4.512 cm

  6. Rainfall intensity I₅₀I₅₀ = R₅₀(tc)tc

    I₅₀ = 4.5120.604 = 7.465 cm/h = 74.65 mm/h

  7. Design discharge Q₅₀Q₅₀ = 0.278·C·I₅₀·A

    Q₅₀ = 0.278 × 0.691 × 74.65 × 2.54 = 36.43 m³/s

    This is the 50-year flood used for railway bridge waterway, scour depth and HFL.