Head loss in pipes: Reynolds number and Darcy–Weisbach
Laminar or turbulent, how to get the friction factor, and how to work out the head lost in a water main.
Water flowing through a pipe loses energy to friction against the wall. Estimating that head loss sizes every pump and water main.
Reynolds number
Re = ρ V Dμ = V Dν
| Re | Flow |
|---|---|
| below 2000 | Laminar |
| 2000 to 4000 | Transition |
| above 4000 | Turbulent |
Water at 20 °C has ν ≈ 1.0 × 10⁻⁶ m²/s, so almost every water supply pipe runs turbulent.
Darcy–Weisbach equation
hf = f LD V²2 g
f is the Darcy friction factor (dimensionless). Some books use f' = f/4 with 4f'.
Getting f
- Laminar: f = 64 / Re.
- Turbulent, smooth pipe (Re up to 10⁵): Blasius, f = 0.316 / Re1/4.
- Turbulent, rough pipe: Colebrook–White, read from the Moody chart, or the explicit Swamee–Jain formula:
f = 0.25[ log₁₀ ( ε/3.7D + 5.74/Re0.9 ) ]²
where ε is the wall roughness (about 0.26 mm for cast iron, 0.0015 mm for PVC).
Worked example
A 300 mm cast iron main, 1.5 km long, carries 0.1 m³/s of water. Take f = 0.02.
V = 0.1π × 0.3² / 4 = 1.41 m/s
hf = 0.02 × 15000.3 × 1.41²2 × 9.81 = 10.2 m
Minor losses
Bends, valves and entrances add losses of K × V²/2g. A sudden enlargement loses (V₁ − V₂)²/2g. In long mains these are small; in pump houses full of fittings they can be large.
Work through these steps with a Moody chart in our pipe flow tool.